Hit-products Logic 3 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Czujniki Hit-products Logic 3. Hit Products Logic 3 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Logic 2
and
Logic 3
Two Wire Irrigation Controllers
P.O. Box 929, 556 S. Mirage Avenue
Lindsay, CA 93247
For Technical Assistance: 800-468-0071 ext. 331
MADE IN THE USA
UPDATED 3/03/03
Read Entire Instruction Booklet Before Installation
Przeglądanie stron 0
1 2 3 4 5 6 ... 23 24

Podsumowanie treści

Strona 1 - and

Logic 2 and Logic 3 Two Wire Irrigation Controllers P.O. Box 929, 556 S. Mirage Avenue Lindsay, CA 93247

Strona 2 - TABLE OF CONTENTS

Pre Wet and Fertigation option: Press set 5, the display will now be the same, except with the following changes, a “P” will show in front of Hours.

Strona 3 - INSTALLING THE LOGIC

Position 4 Start Time To set start times, use set 1 to choose the desired program, use set 2 to choose the start number, (always use start 1 for the f

Strona 4 - VALVE WIRING

Definitions: Start: This is the day of the calendar that the program will start. This will be automatically set upon initial programming or set by t

Strona 5 - Example 1

Note: Program 6 can be sensor activated, such as a temperature sensor. The terminals for remote operation are located on the terminal board and marke

Strona 6 - WIRE CONNECTIONS:

Position 10 Semi/ Manual/ Program Clear Master Clear – Special Feature Button Semi- use set 1 to choose the program you want to activate for one cycle

Strona 7 - BLUE LINE 2

DIAMOND SETTINGS The DS as we call it, is an automatic calendar setting after run times and start times are entered. The DS will set the minimum days

Strona 8 - Fertigation

To Program Receivers, the following must happen. Rotate dial to position 12, press set 5, the display will change to “set receiver ID”, press set 2 or

Strona 9

Programmable Receiver Number Identification Tags Hit Products has developed a user friendly, flexible means to identify the number of the field-progra

Strona 10 - Definitions:

Logic “RAIN OFF” Switch Wiring Instructions Location: The rain off terminal is located on the bottom right of the Controller board labeled “RAIN OFF”

Strona 11

CALENDAR ODD / EVENPRE WET / FERTIGATIONMASTER CLEARPROGRAM RECEIVERFERTIGATION ONMASTER ONCALENDAR ODD / EVENPRE WET / FERTIGATIONMASTER CLEARPRO

Strona 12

TABLE OF CONTENTS 1. Installing the Logic 2 and Logic 3, Valve Wiring 2. Valve Wiring 3. Selecting Proper Wire Size 4. Wire Connections 5.

Strona 13

For Wire Size Formula is: VD = C x R x (2L) / 1000 "Ohms Law" Voltage Drop = Current x Resistance in Ohms VD = Voltage Drop C = Current (

Strona 14

For Wire Size Formula is: VD = C x R x (2L) / 1000 "Ohms Law" Voltage Drop = Current x Resistance in Ohms VD = Voltage Drop C = Current

Strona 17

CALENDAR ODD / EVENPRE WET / FERTIGATIONMASTER CLEARPROGRAM RECEIVERFERTIGATION ONMASTER ONNOTE: INSTALL SPD-F EVERY 300 TO 500 FEET ALON

Strona 18

INSTALLING THE LOGIC Mounting the controller. . .When seleting the controller installation location, make sure controller and all related wiring is

Strona 19

VALVE WIRING The field wiring from the controller to the receivers consists of either one or two, 2-wire runs, which connect, in series, to each valv

Strona 20

The Logic is designed to allow for a 7 volt loss in the field wiring. By increasing the wire size you decrease the voltage loss. The rule is the bigg

Strona 21

Example 2 Logic 1 To Valve 12 Ga Table Voltage drop from Chart Controller to V1 500´@ 3 valves 1.215 V.D. V1 to V2 700´@ 2 valves 1.134 V.D. Tot

Strona 22

Do not use pre-filled wire nut connectors as they will impede the transfer of the signal through the wire splice. TEST BEFORE BACK-FILLING TRENCH.

Strona 23

Controller Lightning Protection It is recommended that, in environments where either power surges or direct lightning strikes are possible, the follo

Strona 24 - THE RUN AS SHOWN

FEATURES LOGIC 2 LOGIC 3 Stations Available 1-42 1-128 Programs Available 8 16 Run Time Per Station 0-10 hours, 59 min. Max. 0-10 hours, 59 mi