24
: Turn rotary switch to position 10. Use set 4 to choose program clear, the display
will change, use set 1 to choose the program that you desire to clear all the information from, use
set 2 to answer yes. Set 3 can be used to exit prior to clearing program.
By clearing the program all information for that program is deleted.
: will clear all the information in the controller by way of the following: Turn rotary
switch to position 10, press set 4, display will change, and then press set 4 again.
All information data in all programs will be deleted. Only the current time and date will
remain.
Set 3 can be used to exit prior to performing a Master Clear.
Position 10 | | Semi / Manual / Program / Master Clear | | Current Monitoring Position Current Monitor-